Mitsubishi Electric R16MTCPU Programming Manual page 82

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

■Operation
Outline operation between CPUs at the MP.GINT and DP.GINT instruction execution is shown below.
• MP.GINT instruction
Sequence program
MP.GINT instruction
CPU dedicated transmission
(Non-Fixed cycle)
PLC interrupt event task
Complete device (D1+0)
Status display device (D1+1)
at the completion
• DP.GINT instruction
Sequence program
DP.GINT instruction
CPU dedicated transmission
(Fixed cycle)
PLC interrupt event task
Complete device (D1+0)
Status display device (D1+1)
at the completion
*1 Set in [System Parameter]  [Multiple CPU settings] in GX Works3
Operation error
• The abnormal completion in the case shown below, and the error code is stored in the device specified with the complete
status storage device (D2). If the complete status storage device (D2) is omitted, an error is not detected and operation
becomes "No operation".
*1
Complete status
Error factor
(Error code) (H)
0010
Instruction request to Motion CPU from PLC CPU exceeds the permissible value.
2282
The interrupt pointer No. set in the M(P).GINT/D(P).GINT instruction is outside the
range of 0 to 15.
*1 0000H (Normal)
• An operation error occurs, "Latest self-diagnosis error detection (SM0)" is turned on, and an error code is stored in "Latest
self-diagnosis error (SD0)" in the cases shown below.
*1
Error code (H)
Error factor
2800
The start I/O number (the first 3 digits when expressed in 4-digit hexadecimal) of the
specified other CPU module is outside the range of 3E0H to 3E3H.
2801
The specified other CPU module is wrong.
*1 0000H (Normal)
2 MOTION DEDICATED PLC INSTRUCTION
80
2.2 Motion Dedicated PLC Instruction
ON MP.GINT execution
Request data set
Transfer
Response
data set
DP.GINT execution
ON
Request data set
Transfer
Communication
*1
cycle
• The reserved CPU is specified.
• The uninstalled CPU is specified.
END
END
Event task executed processing
to the other Motion CPU
ON
ON: Abnormal completion only
1 scan
END
END
Transfer
Response
data set
Event task executed processing
to the other Motion CPU
ON
ON: Abnormal completion only
1 scan
Corrective action
Check the sequence program, and correct it.
Corrective action
Check the sequence program, and correct it.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R64mtcpuMelsec iq-r seriesR32mtcpu

Table of Contents