Mitsubishi Electric MELSEC-Q series User Manual page 96

Programmable controller current transformer input module
Hide thumbs Also See for MELSEC-Q series:
Table of Contents

Advertisement

Address
Address
(decimal)
(hexadecimal)
DD
221
H
DE
222
H
DF
223
H
E0
224
H
E1
225
H
E2
226
H
E3
227
H
E4
228
H
E5
229
H
E6
230
H
E7
231
H
E8
232
H
E9
233
H
EA
234
H
to
to
12B
299
H
12C
300
H
12D
301
H
12E
302
H
12F
303
H
130
304
H
131
305
H
132
306
H
133
307
H
134
308
H
135
309
H
136
310
H
137
311
H
138
312
H
139
313
H
13A
314
H
13B
315
H
13C
316
H
13D
317
H
13E
318
H
13F
319
H
140
320
H
141
321
H
142
322
H
143
323
H
144
324
H
94
Name
CH2 User range setting gain value
CH3 User range setting offset value
CH3 User range setting gain value
CH4 User range setting offset value
CH4 User range setting gain value
CH5 User range setting offset value
CH5 User range setting gain value
CH6 User range setting offset value
CH6 User range setting gain value
CH7 User range setting offset value
CH7 User range setting gain value
CH8 User range setting offset value
CH8 User range setting gain value
System area
Peak current detection setting
Peak current detection flag
CH1 Peak current detection count reset request
CH2 Peak current detection count reset request
CH3 Peak current detection count reset request
CH4 Peak current detection count reset request
CH5 Peak current detection count reset request
CH6 Peak current detection count reset request
CH7 Peak current detection count reset request
CH8 Peak current detection count reset request
CH1 Peak current detection count reset complete
CH2 Peak current detection count reset complete
CH3 Peak current detection count reset complete
CH4 Peak current detection count reset complete
CH5 Peak current detection count reset complete
CH6 Peak current detection count reset complete
CH7 Peak current detection count reset complete
CH8 Peak current detection count reset complete
CH1 Peak current detection time
CH2 Peak current detection time
CH3 Peak current detection time
CH4 Peak current detection time
CH5 Peak current detection time
CH6 Peak current detection time
CH7 Peak current detection time
Default
Read/Write
*1
value
*2
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
00FF
R/W
H
0000
R
H
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R
0
R
0
R
0
R
0
R
0
R
0
R
1000
R/W
1000
R/W
1000
R/W
1000
R/W
1000
R/W
1000
R/W
1000
R/W
Set value
backup area
*3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents