Siemens SINAMICS S120 Function Manual page 314

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic Information about the Drive System
Data sets
Note
In STARTER, you can copy the command data sets (Drive –> Configuration –>
"Command data sets" tab page).
You can select the displayed command data set in the relevant STARTER
screens.
Copying a drive data set
Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied
(target)
3. p0819[2] = 1
Start copying.
Copying is finished when p0819[2] = 0.
Note
In STARTER, you can set the drive data sets via the drive configuration.
Function diagram overview (refer to the List Manual)
S 8560
S 8565
S 8570
S 8575
5-314
Command data set (CDS)
Drive data set (DDS)
Encoder data set (EDS)
Motor data set (MDS)
© Siemens AG 2006 All Rights Reserved
SINAMICS S120 Function Manual, 03/2006 Edition