Servo control
Motor data
Motor data input requires the following parameters:
Table 3-8
Motor data
Induction motor
S
p0304 rated motor voltage
S
p0305 rated motor current
S
p0307 rated motor power
S
p0308 rated motor power factor
S
p0310 rated motor frequency
S
p0311 rated motor speed
S
p0320 rated motor magnetizing current
S
p0322 maximum motor speed
S
p0350 motor stator resistance, cold
S
p0353 motor series inductance
S
p0354 motor rotor resistance, cold
S
p0356 motor stator leakage inductance
S
p0358 motor rotor leakage inductance
S
p0360 motor magnetizing inductance
S
p0400ff encoder data
3-100
Permanent-magnet synchronous motor
S
p0305 rated motor current
S
p0311 rated motor speed
S
p0314 motor pole pair number
S
p0316 motor torque constant
S
p0322 maximum motor speed
S
p0323 maximum motor current
S
p0341 motor moment of inertia
S
p0350 motor stator resistance, cold
S
p0353 motor series inductance
S
p0356 motor stator leakage inductance
S
p0400ff encoder data