ScreenMaster RVG200
Paperless recorder
7.10.7 Slave authorization
Note. This tab is displayed only if only if Implementation on the MODBUS TCP tab is set to Slave – see
page 121.
Slave Authorization
TCP Slave Access
Note. The following parameter is displayed only if TCP Slave Access is not set to Unrestricted.
Authorized IP 1 (to 6)
OI/RVG200-EN
Select the maximum number of simultaneous TCP / IP connections
permitted:
Unrestricted
–
any number of MODBUS TCP Slave devices are
permitted to poll the recorder.
1 (to 6)
–
only the MODBUS TCP slave device(s) whose IP
address(es) is (are) entered in the Authorized IP 1 (to
Authorized IP 6) parameter(s) (below) is (are) permitted
to poll the recorder.
Enter the IP address(es) of the MODBUS TCP Slave (MODBUS Master)
device(s) that is (are) permitted to poll the recorder for data.
7 Configuration
123