(8) Blank paper count specification

Mode
Print mode
Normal
Without print
(Invalid paper exit)
Without print
(Blank paper insertion)
Single face print
(Single face mode)
Single face print
(Duplex mode)
Duplex print
Front cover
Without print
With print (Single face)
With print (Duplex)
Back cover
Without print
With print (Single face)
With print (Duplex)
Insert paper
Without print
With print (Single face)
With print (Duplex)
OHP insert
Without print
paper
With print (Single face)
With print (Duplex)
* Large size: A3, 11 x 17. (Greater size than paper length 384mm)
*1: Follows SIM 26-5 (Count-up mode). (Default: Double count-up (Set value: 2))
( ): Large size single count-up setting (Count-up number when set to 1.)
: Counts up.
✕ : Does not count up.
: Follows SIM 26-52 setting.
0 : Does not count up. (Japan/SCA default)
— : Out of target (No print process)

(9) Consumables counter specification

Counter
OPC drum counter
OPC drum rotation counter (sec)
Developer counter
Developing roller rotation counter
(sec)
Toner counter
Toner supply counter (sec)

(10) Reset and set for suplly counters

Work item
Setting the toner concentration control
level
Reset the OPC drum counter
Reset the Developer counter
Reset the OPC drum running time
counter (sec)
Reset the DV running time counter (sec)
Count attribute
Print surface
Front
Back
surface
surface
1: Counts up. (Other default)
Simplex print
Count-up
Paper feed tray – Main
timing
unit paper exit
Small size
When transfer is
1
completed
When transfer is
completed
When transfer is
1
completed
When transfer is
completed
When transfer is
1
completed
When transfer is
completed
Simulation
SIM 25-2
Developer counter
DV unit running time counter (sec)
SIM 24-7
OPC drum counter
SIM 24-5
Developer counter
SIM 24-11
OPC drum running time counter (sec)
SIM 24-11
DV unit running time counter (sec)
MX-M700N OTHERS 12 – 4
Blank paper count setting (SIM 26-52)
0: NO
Small
Large
Small
size
size
size
0
0
0
0
0
1
1
2 (1) *1
1
1
2 (1) *1
1
2
4 (2) *1
2
0
0
1
1
2 (1) *1
1
2
4 (2) *1
2
0
0
1
1
2 (1) *1
1
2
4 (2) *1
2
0
0
1
1
2 (1) *1
1
2
4 (2) *1
2
0
0
1
1
2 (1) *1
1
Count-up number
Paper feed tray – ADU
Large size
Small size
Large size
2 (1)
1
2 (1)
1
2 (1)
1
Reset item
1: YES
Large
size
0
2 (1) *1
2 (1) *1
SS/DS
2 (1) *1
SD (Odd number of documents)
4 (2) *1
SD (Even number of documents)/DD
2 (1) *1
2 (1) *1
4 (2) *1
2 (1) *1
2 (1) *1
4 (2) *1
2 (1) *1
2 (1) *1
4 (2) *1
2 (1) *1
2 (1) *1
Duplex print inhibition
Duplex print
ADU – Paper feed tray
Small size
Large size
2 (1)
1
2 (1)
2 (1)
1
2 (1)
2 (1)
1
2 (1)
Included Test Command
Remark
Clear
Sim24-7
Sim24-11
Sim24-5
Sim24-11
SIM 24-5
SIM 24-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-m620uMx-m700uMx-m620nMx-m550nMx-m700n