F2-32

Process control trouble

(Drum marking scan trouble)
Details
The drum marking size, density, or the number of
units is improper.
Section
Engine
Case 1
Cause
Drum marking sensor trouble
Check and
Use SIM 44-02 to perform the process control
remedy
sensor gain adjustment.
Case 2
Cause
Improper connection of the harness between the
PCU PWB and the drum marking sensor
Check and
If "Error" is displayed, it may be considered as a
remedy
breakdown. Check the sensor and the harness.
Case 3
Cause
The drum marking sensor is dirty.
OPC drum cleaning trouble
Check and
If the adjustment is completed, check the drum
remedy
surface conditions.
F2-37
Drum marking sensor gain adjustment
error
Details
Before starting process control, the drum marking
area surface is read by the sensor to make the
sensor gain adjustment so that the output is fixed
to a certain level. Though the sensor gain is
changed, the output is not fixed to a certain level.
Section
Engine
Case 1
Cause
Drum marking sensor trouble
Check and
Use SIM 44-02 to perform the process control
remedy
sensor gain adjustment.
Case 2
Cause
Improper connection of the harness between the
PCU PWB and the drum marking sensor
Check and
If "Error" is displayed, it may be considered as a
remedy
breakdown.
Check the sensor and the harness.
Case 3
Cause
The drum marking sensor is dirty.
OPC drum cleaning trouble
Check and
If the adjustment is completed, check the drum
remedy
surface conditions.
F2-39

Process thermistor breakdown

Details
When the input value of the process thermistor is
detected as 235 or greater or 22 or smaller for 3
times continuously.
Section
Engine
Case 1
Cause
Improper connection of the process thermistor
harness.
Check and
Check connection of the connector and the
remedy
harness of the process thermistor.
Case 2
Cause
Process thermistor trouble
Check and
Check the process thermistor.
remedy
Case 3
Cause
PCU PWB trouble
Check and
Check the PCU PWB.
remedy
MX-M700N SELF DIAG AND TROUBLE CODE 8 – 14
F2-46

Developing thermistor breakdown

Details
When the input value of the process thermistor is
detected as 244 or greater or 20 or smaller for 3
times continuously
Section
Engine
Case 1
Cause
Developing thermistor harness connection trouble
Check and
Check connection of the connector and the
remedy
harness of the developing thermistor.
Case 2
Cause
Developing thermistor harness trouble
Check and
Check the developing thermistor
remedy
Case 3
Cause
PCU PWB trouble
Check and
Check the PCU PWB.
remedy
F2-47
Room temperature thermistor
breakdown
Details
When the input value of the process thermistor is
detected as 235 or greater or 22 or smaller for 3
times continuously.
Section
Engine
Case 1
Cause
Improper connection of the room temperature
thermistor harness.
Check and
Check connection of the connector and the
remedy
harness of the process thermistor.
Case 2
Cause
Room temperature thermistor trouble
Check and
Check the room temperature thermistor.
remedy
Case 3
Cause
PCU PWB trouble
Check and
Check the PCU PWB.
remedy
F2-48
Developing humidity sensor break
down
Details
When the output value of the development
humidity sensor is detected as 38 or smaller or
255 or greater.
The output value is the average value of 5
sampling data in the interval of 100ms.
Section
Engine
Case 1
Cause
Developing humidity sensor harness connection
trouble
Check and
Check connection of the connector and the
remedy
harness of the developing humidity sensor.
Case 2
Cause
Developing humidity sensor trouble
Check and
Check the developing humidity sensor
remedy
Case 3
Cause
PCU PWB trouble
Check and
Check the PCU PWB.
remedy