SIMULATION 14
TROUBLE CANCELLATION. (OTHERS)
ARE YOU SURE?
1. YES
2. NO
15
15-0
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose) Used to cancel the self-diag "U6-09, F3-12,
22" (large capacity paper feed tray, paper
feed trays 1, 2) troubles.
Section
LCC
Operation/Procedure
1)
Select 1 (YES) with 10-key.
2)
Press [START] key. (The trouble display is canceled.)
1
YES
After canceling the LCC trouble, the machine returns
to the main code entry standby mode.
2
NO
Without canceling the trouble, the machine returns to
the main code entry standby mode.
SIMULATION 15
LCC TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose) Used to cancel the self-diag U2 troubles.
Section
MFP control PWB, PCU PWB, scanner
control PWB
Operation/Procedure
1)
Select 1 (YES) with 10-key.
2)
Press [START] key. (The trouble display is canceled.)
1
YES
After canceling the U2 trouble, the machine returns to
the main code entry standby mode.
2
NO
Without canceling the trouble, the machine returns to
the main code entry standby mode.
SIMULATION 16
U2 TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
17
1
17-0
Purpose
Function (Purpose) Used to cancel the PF troubles (when the
Section
Operation/Procedure
1)
Select 1 (YES) with 10-key.
2)
Press [START] key. (The trouble display is canceled.)
1
2
SIMULATION 17
PF TROUBLE CANCELLATION.
ARE YOU SURE?
1. YES
2. NO
21
1
21-1
Purpose
Function (Purpose) Used to set the maintenance cycle.
Section
Operation/Procedure
1)
Enter the number corresponding to the maintenance timing
display.
2)
Press [START] key. The condition entered in procedure 1) is
set.
0
1 - 300
999
SIMULATION 21-1
MAINTENANCE CYCLE SETUP. INPUT VALUE 0-999, AND PRESS
START.
0:
1-300: MAINTENANCE CYCLE (1K-300K)
999:
1
MX-M700N SIMULATION 7 – 17
Clear/Cancel (Trouble etc.)
copy inhibit command from the host com-
puter is received).
Communication unit
(RIC/MODEM etc.)
YES
After canceling the PF trouble, the machine returns to
the main code entry standby mode.
NO
Without canceling the trouble, the machine returns to
the main code entry standby mode.
Setting
Specifications - Counter
Maintenance timing display
Default (Differs depending on the model.)
Maintenance display at 1K - 300K
No maintenance display
DEFAULT
FREE
1
Setting
range
0 - 999
0