Sharp MX-M550U Service Manual page 149

Digital multifunctional system
Hide thumbs Also See for MX-M550U:
Table of Contents

Advertisement

SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
50
3.TRAY2
50
5.TRAY4
50
6.BPT
50
8.ADU
50
9.SPF(TOP)
11.SPF(LOW)
50
13.SPF FEED(HIGH)
50
53
53-6
Purpose
Adjustment
Function (Purpose) Used to adjust the DSPF width detection
level.
Section
Operation/Procedure
1)
Open the SPF paper feed guide to the maximum width posi-
tion.
2)
Select MAX. POSITION with 10-key.
3)
Press the [START] key.
The max. width detection level is recognized.
4)
Press the [SYSTEM SETTINGS] key.
5)
Open the SPF paper feed guide to the width for the A4R size.
6)
Select POSITION 1 with 10-key.
7)
Press the [START] key.
The A4R width detection level is recognized.
8)
Press the [SYSTEM SETTINGS] key.
9)
Set the manual paper feed guide to A5R size width.
10) Select POSITION 2 with 10-key.
11) Press the [START] key.
The A5R width detection level is recognized.
12) Press the [SYSTEM SETTINGS] key.
13) Open the SPF paper feed guide to the minimum width position.
14) Select MIN. POSITION with 10-key.
15) Press the [START] key.
The minimum width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
4.TRAY3
50
7.LCC
50
50
10.SPF(HIGH)
50
12.SPF FEED(TOP)
50
14.SPF FEED(LOW)
50
MX-M700N SIMULATION 7 – 55
53-7
Purpose
Function (Purpose) Used to enter the SPF width detection
1
Section
Operation/Procedure
1)
Select the number corresponding to the set item with 10-key.
1
MAX.
POSITION
2
POSITION 1
3
POSITION 2
4
MIN. POSITION
2)
Press the [START] key.
3)
Enter the set value with 10-key.
4)
Press the [START] key.
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION:
2.POSITION 1
3.POSITION 2
4.MIN.POSITION:
53-8
Purpose
Function (Purpose) Used to adjust the document scan start
Section
Operation/Procedure
1)
Enter 2 with 10-key.
2)
Press the [START] key.
3)
Enter the adjustment value with 10key. (1 count: 0.1mm)
4)
Press the [START] key.
2
MANUAL
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. PRESS START.
1
2.MANUAL
Adjustment/Setup/Operation data output/
Check (Display/Print)
adjustment value.
DSPF
Item
Max. position
Adjustment point 1
Adjustment point 2
Min. width
66
:
456
:
713
791
Adjustment
position. (Used to adjust the scanner scan
position in the SPF mode front scan.)
Item
Manual adjustment
(Direct entry of a
number)
25
Setting
Default
range
0 - 1023
66
456
713
791
1
Setting
Default
range
1 - 70
32