Sharp MX-M550U Service Manual page 122

Digital multifunctional system
Hide thumbs Also See for MX-M550U:
Table of Contents

Advertisement

: '07 Feb 15
1
26-30
Purpose
Setting
Function (Purpose) Used to set the operation mode conforming
to the CE mark (Europe safety standards).
(Conforming to soft start when driving the
fusing heater lamp.)
Section
Operation/Procedure
1)
Select the number that corresponds to the operation mode
with 10-key.
2)
Press the [START] key.
0
NO
CE mark control NO (Normal operation)
1
YES
CE mark control YES (Heater lamp soft start
operation)
(Default: 1 for Europe, Australia, China, 0 for the others)
1
SIMULATION 26-30
CE MARK CONTROL SETTING. SELECT 0-1, AND PRESS START.
0. NO
1. YES
26-35
Purpose
Setting
Function (Purpose) Used to set whether the same continuous
troubles are displayed as one trouble or the
series of troubles with SIM 22-4 when the
same troubles occur continuously.
Section
Operation/Procedure
1)
Select the number that corresponds to the operation mode
with 10-key.
2)
Press the [START] key.
0
ONCE
When two or more troubles of a same kind occur
continuously, the troubles are displayed as one
trouble in the trouble history of SIM22-4.
1
ANY
When two or more troubles of a same kind occur
continuously, the troubles are displayed in the
trouble history of SIM22-4 directly.
(Default: 0)
SIMULATION 26-35
TROUBLE MEMORY MODE SETTING. SELECT 0-1, AND PRESS
START.
0. ONCE
1. ANY
26-38
Purpose
Function (Purpose) Used to set CONTINUE/STOP of printing
Section
Operation/Procedure
1)
Select the number that corresponds to the operation mode
with 10-key.
2)
Press the [START] key.
0
PRINT
CONTINUE
1
PRINT STOP
(Default: 0)
SIMULATION 26-38
LIFE OVER SETTING. SELECT 0-1, AND PRESS START.
0. PRINT CONTINUE
1. PRINT STOP
1
26-41
Purpose
Function (Purpose) Used to set YES/NO of the automatic mag-
Section
Operation/Procedure
1)
Enter the number corresponding to whether AMS operation is
automatically performed or nor in the center binding mode with
the 10-key.
2)
Press the [START] key.
0
1
(Default: 0)
SIMULATION 26-41
PAMPHLET MODE AMS SETTING. SELECT 0-1, AND PRESS
START.
0. NO
1. YES
26-50
Purpose
1
Function (Purpose) Black-White reverse YES/NO setting
Section
Operation/Procedure
1)
Select ENABLE/DISABLE of the B/W reverse mode with 10-
key.
2)
Press the [START] key.
0
DISABLE
1
ENABLE
(Default: 1)
* No B/W reverse function for UK.
SIMULATION 26-50
B/W REVERSE MODE SETTING. SELECT 0-1, AND PRESS
START.
0. DISABLE
1. ENABLE
MX-M700N SIMULATION 7 – 28
Setting
when maintenance timing is over and the
count value reaches 110% of replacement
timing (life).
Others
Print continue
Print stop
Setting
nification ratio selection (AMS) in the pam-
phlet mode.
NO
AMS/APS selection allowed.
(enable AMS manually)
YES
AMS is forcibly operated.
Setting
B/W reverse mode DISABLE
B/W reverse mode ENABLE
1
1
1
1

Hide quick links: