Maximum Link Attempts; Relink Time-Out; Bluetooth/Ism Network Activity Examples - Honeywell Voyager 1200g User Manual

Single-line laser bar code scanner
Hide thumbs Also See for Voyager 1200g:
Table of Contents

Advertisement

Event
Base reset (firmware upgrade or
power cycle)
Scanner reset due to firmware
upgrade
Scanner reset due to battery
change
Scanner placed in different base
unit

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base.
During the connection setup process, the scanner transmits in order to search for and connect to a base. In order to pre-
vent continuous transmissions that could interfere with other users of the ISM band, the number of attempts to connect is
limited by this setting. After the maximum number of attempts is reached, the scanner will not attempt to reconnect to a
base. Pressing the scanner's button or placing the scanner in the base resets the attempt count and the scanner will again
try to link.
Scan the Maximum Link Attempts bar code, then scan the number of attempts for the setting (from 0-255) from the inside
back cover. Scan Save to save the setting. Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause the scanner to try to link until
the Power Time-Out Timer setting (see
Attempts to zero will cause the scanner to only attempt linking one time after a button press.

Relink Time-Out

Relink Time-Out controls the idle time between relink attempts. An attempt to link a scanner to a base typically lasts up to
5 seconds. This is the time when the scanner is actually attempting a contact . Relink Time-Out controls the amount of
time, in seconds, that elapses between the end of one connection attempt and the start of the next.
Scan the Relink Time-Out bar code, then scan the number of seconds for the setting (from 1-100) from the inside back
cover. Scan Save to save the setting. Default = 3 seconds.

Bluetooth/ISM Network Activity Examples

Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect to the base unit. Each attempt consists
of approximately 5 seconds of active time followed by 3 seconds of idle time. After one hour, the scanner powers off and
batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default settings
3 - 18
Auto Reconnect On
Scanner behaves as if out of range.
Relink occurs automatically.
Relink occurs automatically.
Relink to new base occurs automatically.
Maximum Link Attempts
page
3-9) expires. When Auto Reconnect Mode is Off, setting Maximum Link
Relink Time-Out
Auto Reconnect Off
No attempt to relink made while base
is powered off. Button must be
pressed to initiate relinking.

Advertisement