Auto Reconnect Mode

Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is
detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without
user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off.
The table below shows the results of the Auto Reconnect On and Off settings:
Event
Scanner out of range
Base or Access point reset
(firmware upgrade or power cycle)
Scanner power down due to
Power Time-Out Timer setting
(see
page
3-11)
Scanner reset due to firmware
upgrade
Scanner reset due to battery
change
Scanner placed in different base
unit

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base or an
Access Point. During the connection setup process, the scanner transmits in order to search for and connect to a base or
an Access Point. In order to prevent continuous transmissions that could interfere with other users of the ISM band, the
number of attempts to connect is limited by this setting. After the maximum number of attempts is reached, the scanner will
not attempt to reconnect to a base or an Access Point. Pressing the trigger, scanning an Access Point linking bar code, or
placing the scanner in the cradle resets the attempt count and the scanner will again try to link.
3 - 24
Auto Reconnect On
Relink occurs automatically. If maximum
number of link attempts is unsuccessful,
then the scanner must be relinked by
either pulling the trigger, placing the
scanner in the base, or scanning the
Access Point linking bar code. (See
"Maximum Link Attempts" on page 3-24.)
Scanner behaves as if out of range.
Trigger must be pulled, Access Point linking bar code must be scanned, or the
scanner must be placed in the base unit to relink.
(Note: scanner relinks on power up, but powers on due to one of the above
actions.)
Relink occurs automatically.
Relink occurs automatically.
Relink to new base occurs automatically.
Auto Reconnect Off
Auto Reconnect Off
The scanner is relinked by pulling the
trigger, or scanning the Access Point
linking bar code.
No attempt to relink made while base
or Access Point is powered off.
Trigger must be pulled to initiate
relinking.