The table below shows the results of the Auto Reconnect On and Off set-
tings:
Event
Scanner out of
range
Base or Access
point reset
(firmware upgrade
or power cycle)
Scanner power
down due to Power
Time-Out Timer
setting (see
8)
Scanner reset due
to firmware
upgrade
Scanner reset due
to battery change
Scanner placed in
different base unit

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scan-
ner tries to form a connection with a base or an Access Point. During the
connection setup process, the scanner transmits in order to search for and
connect to a base or an Access Point. In order to prevent continuous trans-
missions that could interfere with other users of the ISM band, the number
3 - 34
Auto Reconnect On
Relink occurs
automatically. If
maximum number of link
attempts is
unsuccessful, then the
scanner must be
relinked by either pulling
the trigger, placing the
scanner in the base, or
scanning the Access
Point linking bar code.
(See
Maximum Link
Attempts
Scanner behaves as if
out of range.
Trigger must be pulled, Access Point linking bar
code must be scanned, or the scanner must be
placed in the base unit to relink.
page 4-
(Note: scanner relinks on power up, but powers
on due to one of the above actions.)
Relink occurs automatically.
Relink occurs automatically.
Relink to new base occurs automatically.
on page 3-34.)
Auto Reconnect Off
The scanner is
relinked by pulling the
trigger, or scanning
the Access Point
linking bar code.
No attempt to relink
made while base or
Access Point is
powered off. Trigger
must be pulled to
initiate relinking.