Shutting Down The Sce Platform - Cisco SCE 1000 Installation And Configuration Manual

Hide thumbs Also See for SCE 1000:
Table of Contents

Advertisement

Rebooting and Shutting Down the SCE Platform

Shutting Down the SCE Platform

Shutting down the SCE 1000 platform is required before turning the power off. This helps to
ensure that non-volatile memory devices in the SCE 1000 platform are properly flushed in an
orderly manner.
Note
When the SCE platform restarts, it loads the startup configuration, so all changes made in the running
configuration will be lost. You are advised to save the running configuration before performing reload,
as described in
To shut down your SCE 1000 platform, complete the following steps:
Step 1
Connect to the serial console port (The CON connector on the SCE 1000 platform front panel,
9600 baud).
The SCE 1000# prompt appears.
Type reload shutdown.
Step 2
A confirmation message appears.
Type Y to confirm the shutdown request and press Enter.
Step 3
E
XAMPLE
The following example shows the commands for system shutdown.
SCE 1000#reload shutdown
You are about to shut down the system.
The only way to resume system operation after this
is to cycle the power off, and then back on.
Continue?
y
IT IS NOW SAFE TO TURN THE POWER OFF.
Since the SCE 1000 platform can recover from the power-down state only by being physically turned
Note
off (or cycling the power), this command can only be executed from the serial CLI console. This
limitation helps prevent situations in which a user issues this command from a Telnet session, and then
realizes he/she has no physical access to the SCE 1000 platform.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
7-10
Saving the Configuration Settings
:
Chapter 7
Basic SCE 1000 Platform Operations
(on page 7-6).