Cisco SCE 1000 Installation And Configuration Manual page 76

Hide thumbs Also See for SCE 1000:
Table of Contents

Advertisement

Initial System Configuration
Step 6
If you entered a specific IP address, enter the wildcard bits to define a range of IP addresses and
press Enter. (See
To define an individual IP address, type 0.0.0.0 and press Enter.
There is no default for this parameter.
Enter wildcard bits:
The maximum number of entries in an ACL is 20.
Step 7
If the "any" option was used, no other IP addresses may be added to the list.
Would you like to add another entry to this list? [no]:y
Enter up to 20 entries as described in step 5 and step 6.
Would you like to add another entry to this list? [no]:
When all entries are added to one list, you are asked whether you would like to create another
Step 8
ACL. You may define up to 99 ACLs.
Would you like to configure another list? [no]: y
Enter up to 20 IP addresses in this new ACL, as described in step 5 and step 6.
Would you like to configure another list? [no]:
You are now prompted to assign the desired ACLs to restrict IP and Telnet access.
Restrict IP access to the SCE 1000 by assigning the appropriate ACL.
Step 9
Type the number of the ACL to be assigned to IP access and press Enter.
To accept the default ACL, press Enter.
Enter IP access-class [0]:
Step 10
Restrict Telnet access to the SCE 1000 by assigning the appropriate ACL.
Type the number of the ACL to be assigned to the Telnet interface and press Enter.
To accept the default ACL, press Enter.
Enter Telnet access-class [0]: 2
E
XAMPLE
This example illustrates a common access control scenario. Let us assume the following:
We want to permit every station to access the SCE on the management port (e.g. ping, SNMP
polling etc.).
We want to restrict Telnet access to only a few permitted stations.
We therefore need to create two access control lists:
For general IP access — permit access to all IP addresses.
For Telnet — permit access to the specified IP address, and deny to all others.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
5-14
Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
Entry Formats
To add more entries, type y and press Enter
When all entries have been added, press Enter
To create another ACL, type y and press Enter
When all ACLs have been created, press Enter.
:
(on page 5-12).)