Cabling the Line Ports and Completing the Installation

Configure GigabitEthernet Auto-Negotiation

By default, the SCE 1000 GBE line interface ports are configured with auto-negotiation disabled.
Auto-negotiation must be disabled when the SCE 1000 is deployed via an external optical splitter
Note
(receive-only topology)
.
Note
If you change any parameters, you must save the new configuration settings.
Type copy running-config startup-config, and press Enter
To enter the Global Configuration Mode, at the SCE 1000# prompt, type configure, and press
Step 1
Enter.
The SCE 1000(config)# prompt appears.
To enter the desired GBE port interface, type interface GigabitEthernet 0/portnumber, and
Step 2
press Enter, where portnumber is the number of the selected port (1 or 2).
The SCE 1000(config if)# prompt appears.
Type auto-negotiate and press Enter.
Step 3
The SCE 1000(config if)# prompt appears.
Step 4
To return to Global Configuration Mode, type exit and press Enter.
The SCE 1000(config)# prompt appears.
Repeat this procedure to configure auto-negotiation for the other GBE port interfaces as needed.

Connecting the GBE Line Interface Ports

The following sections present the general procedure for cabling the GBE interface ports. Refer to
Cabling Diagrams
system for the specific connections required.
When installing an External Optical Bypass module, the SCE 1000 line ports are connected to the
Note
module. See
OL-7821-04
(on page 6-1) to find the appropriate cabling diagram for the topology of your
Cabling the External Optical Bypass Module
Cisco SCE 1000 2xGBE Installation and Configuration Guide
Connecting the line ports to the network
(on page A-4) for complete instructions.
6-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sce 1000 2xgbe

Table of Contents