Configuring SPA9000 Connectivity for PSTN Access Only
You can configure the SPA9000 so that the users can place and receive calls through PSTN lines that
are connected to a SPA400, or to multiple SPA400 devices . Set up a line interface for each SPA400 that
you connect .
NOTE:
This step is required if you want to configure another SPA400 for PSTN access only .
1 .
Start Internet Explorer, and then enter the IP address of the SPA9000 . Click
then click Advanced .
2 .
Click
Voice tab > Line 3 .
NOTE:
Any line can be used; however, for consistency throughout this Install Guide, Line 1 is used
for ITSP service, Line 2 is used for the SPA400 that has voice mail service, and Line 3 is used for a
second SPA400 that has PSTN access .
3 .
Enter the following information about the SPA400:
User ID:
–
9000
This ID corresponds to the User ID that you entered on the SPA400 configuration page . They
must match exactly .
Proxy:
Enter the IP address of the SPA400 .
–
Register Expires:
–
60
This setting ensures that the SPA9000 and SPA400 are resynchronized every 60 seconds . This
setting ensures that any future changes in settings are synchronized on both devices .
Use the following illustration as a guide .
Submit All Changes .
4 .
Click
Linksys Voice System Installation and Configuration Guide
Configuring Phone Service and Voice Mail
Configuring the SPA9000
Admin Login and
51