Error Number
166
ALTERA count = 0, indicating RPT not connected or failed
167
ALTERA Not complete, indicating RPT input frequency too low
168
ALTERA overflowed, indicating RPT input frequency too high
169
RPT count is out of range at 1000mB
170
Invalid RTC Data
171
RTC Null Pointer
172
Real time clock is not incrementing
173
Real time clock parameter RAM failed
174
Received Serial data is not identical to transmitted test data
175
No Received serial data during loopback test
176
PS apply valve failed - short
177
PS apply valve failed - open
178
PS release valve failed - short
179
PS release valve failed - open
180
PT apply valve failed - short
181
PT apply valve failed - open
182
PT release valve failed - short
183
PT release valve failed - open
184
Solenoid valves have failed when all commanded OFF
185
Solenoid Timer Failed
186
Invalid Solenoid ID
187
SPI Entry parameters are invalid
188
EEPROM Block is null
189
EEPROM invalid device selected
190
EEPROM Block is out of range
191
Water Dump Failed
192
Driver Write
193
Button registration
Description
E
C
RROR
ODES