Unpack and Install the Chassis
Warning
Statement 1252 Equipment Grounding
This equipment must be grounded. To reduce the risk of electric shock, the power cord, plug, or combination
must be connected to a properly grounded electrode, outlet, or terminal.
Warning
Statement 414 Connected To Grounded Outlet
In the Scandinavian countries (Denmark, Finland, Iceland, Norway, and Sweden) the appliance must be
connected to a grounded outlet.
Procedure
Step 1
Locate the chassis grounding receptacles on your router chassis.
You can locate them at the following position:
• At the left side panel, lower section towards the rear
Step 2
Use the wire stripper to strip one end of the 2-AWG wire approximately 0.75 inches (19.05 mm).
Step 3
Insert the 2-AWG wire into the wire receptacle on the grounding lug.
Figure 23: Chassis Ground Receptacles on Cisco 8608 Chassis
1
Locate ground
2
Align the lug holes and tighten the screws
Hardware Installation Guide for Cisco 8600 Series Routers
Locate and Ground the Chassis
37