Honeywell ALERTON ACM-VLX Installation And Operation Manual page 12

Table of Contents

Advertisement

Installation and Operations Guide
MS /TP S upports up to 10
BACne t MS /TP de vice s .
S e e page 32.
AC-2650 to conne ct
compute r for
Hype rTe rminal
configuration or te s ting.
S e e page 40 and
page 69.
Fig ure 8
Communications conne ctions for VLX and EXP
12
|
ACM-VLX/VLX/EXP/AXM
Ethe rne t Cate gory 5 or be tte r drop cable
with RJ-45 jack. Re comme nde d BACne t
ne twork conne ction. S e e page 31.
POWER
VLX
ASSEMBLED IN USA
POWER: MAX LOAD - 20VA
CLASS 2 CIRCUITS ONL
USE COPPER CONDUCTORS ONL
FOR INDOOR USE ONL
OPEN ENERG MANAGEMENT
E UIPMENT 5K05
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUB ECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MA NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT AN INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MA CAUSE UNDESIRED OPERATION.
DIAGNOSTICS
CPU
FLASHING
NORMAL OPERATION
ON
NORMAL / READ
S S
OFF
SERVICE RE UIRED
ON
ROC LOADED / OPERATIONAL
ROC
OFF
ROC DOWNLOAD RE UIRED
DDC
FLASHING
DDC LOADED / OPERATIONAL
STATUS
EXP-2200
ASSEMBLED IN USA
POWER: MAX LOAD - 20VA
24VDC SOURCE - 250mA TOTAL
CLASS 2 CIRCUITS ONLY
USE COPPER CONDUCTORS ONLY
FOR INDOOR USE ONLY
OPEN ENERGY MANAGEMENT
EQUIPMENT 5K05
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
STATUS
H-O-A
EXP-1048
H-O-A
ASSEMBLED IN USA
H-O-A
H-O-A
POWER:
MAX LOAD - 68VA
H-O-A
NO BO S - 20V A
24VDC SOURCE - 250mA TOTAL
CLASS 2 CIRCUITS ONL
USE COPPER CONDUCTORS ONL
H-O-A
FOR INDOOR USE ONL
H-O-A
H-O-A
H-O-A
H-O-A
OPEN ENERG MANAGEMENT
E UIPMENT 5K05
H-O-A
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUB ECT TO THE FOLLOWING TWO CONDITIONS:
H-O-A
(1) THIS DEVICE MA NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT AN INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MA CAUSE UNDESIRED OPERATION.
BO 0
BO 1
BO 2
BO 3
AO 0
AO 1
AO 2
AO 3
AO 4
AO 5
AO 6
AO 7
© Honeywell. All Rights Reserved. LT-VLXEXPAXMIOG Rev. 01
Pane l g ro und to te rminate s hie lds
and unit ground. S e e page 25.
EXP
c o mmunic atio ns
c able 18 AWG two
conductor twis te d-
s hie ld cable . 18"
(457mm) max.
be twe e n units .
Te rminating
re s is to rs 120 Ohm
matche d pre cis ion
te rminating re s is tors
at e ach e nd.
S hie ld Run one e nd to
pane l ground, tape back
at othe r e nd. Tie through
at inte rme diate EXPs .