INTRODUCTION
The SpectrumXIO family of devices are intended to be
replacement devices for the original Novar Legacy
Spectrum Rack Input and Output modules that have been
previously installed. These modules include the following
modules: Rack Input Module, Rack Output Module,
Compressor Output Module, Condenser Control module,
Analog Output Module, Case Input Module 2, and 8-Input
Module.
Fig. 2. XIO family of Spectrum System Remote I/O (for reference only).
MOUNTING AND WIRING INSTRUCTIONS
Fig. 1. XIO Output device with HOA switches.
Introduction ..................................................................................
Specifications ...............................................................................
Mounting ........................................................................................
Wiring ..............................................................................................
Spectrum Network Wiring .......................................................
Model and Part Numbers ........................................................ 10
Regulatory Compliance ............................................................ 16
Contents
1
3
4
5
8
8
31-00360-01

Advertisement

loading

Summary of Contents for Honeywell Multisite XIO Series

  • Page 1: Table Of Contents

    XIO Family of Spectrum System Remote Input/Output Devices MOUNTING AND WIRING INSTRUCTIONS INTRODUCTION The SpectrumXIO family of devices are intended to be replacement devices for the original Novar Legacy Spectrum Rack Input and Output modules that have been previously installed. These modules include the following modules: Rack Input Module, Rack Output Module, Compressor Output Module, Condenser Control module, Analog Output Module, Case Input Module 2, and 8-Input...
  • Page 2 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Table 1. XIO Model Types. Power Consumption Model Part Number Module Type Mode IO Count (VA) xio.RIM XIO-RIM-S 8 Digital Inputs Configurable Input 8 universal inputs selectable 8 Hi-Temp Inputs Group as a group for either 4 Lo-Temp Inputs 8 digital inputs or 3 Pressure Inputs...
  • Page 3: Specifications

    XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES SPECIFICATIONS Fig. 3. Models xio.RIM, xio-RIMCT, xio.AOM, xio.CIM, xio.8IM. Physical Dimensions (Models xio.RIM, Model Name Weight xio-RIMCT, xio.AOM, xio.CIM, xio.8IM) xio.RIM 0.70 lbs (319g) Width: 5.64 inches (143mm) xio-RIMCT Height: 5.53 inches (141mm) xio.AOM Depth: 1.84 inches (47mm) xio.CIM...
  • Page 4: Mounting

    XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Operating Environment (all models) NOTE: Use Cooper Bussmann type S500-5A or similar. See Table 2 for more information. Humidity: 5% to 95% Relative Humidity, non-condensing Current Transformer Inputs: Operating Temp: -40°F to 158°F (-40° to 70°C) Range = 0- 5A, Accuracy = +/-5% of span.
  • Page 5: Wiring

    XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Din Rail Un-Mounting 1. Remove all wiring connectors from the device to expose DIN latch release 2. Pull down DIN latch release with one hand to release the fastener from the DIN rail. 3.
  • Page 6 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES — If the bus connector method is being used, then the supplied 5-position terminal block cannot be used when attaching additional XIO devices. Terminal Block Wiring Fig. 8. XIO Devices linked via Daisy Chain. Fig.
  • Page 7 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Fig. 10. Terminal Label/PIN configuration for the XIO-RIM-S, XIO-AOM-S, XIO-CIM-S and XIO-8IM-S. Fig. 11. Terminal Label/PIN configuration for the XIO-RIMCT-S. Fig. 12. Terminal Label/PIN configuration for the XIO-ROM-S, XIO-CCM-S-H and XIO-COM-S-H. operating in automatic control. When the switch is in the WARNING Auto (A) position, the LED will be continuously on or off, to match the status of the output relay coil.
  • Page 8: Spectrum Network Wiring

    XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Preparing wiring for terminal blocks: Spectrum Network Wiring 1. Strip 1/2 in. (13 mm) from wires to be attached at A two-conductor shielded cable (see Table 8) should be one terminal. used to make the Master/Slave Network Communications connections from the Novar Spectrum Executive Controller or Spectrum Refrigeration Controller to the 1/2 (13)
  • Page 9 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES value of each of the DIP switches set to OFF (down) patibility. For the XIO-RIM-S model set switches #7 position to determine the address offset value that and #8 according to the settings in Table 6 to select will be added to the model's base address to arrive at input mode options.
  • Page 10: Model And Part Numbers

    XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Model and Part Numbers MAINTENANCE REPLACEMENT Table 8. Novar Part Numbers. Part No. Product Description The XIO family of modules with Spectrum communication was designed with the intent to provide a solution for the XIO-RIM-S 8 Digital Inputs maintenance replacement of existing Novar Spectrum...
  • Page 11 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Replacement of Spectrum Rack Output Module (ROM) Replacement of one legacy Novar Spectrum ROM module requires installation of up to two XIO-ROM-S modules. Each new module must be assigned its own unique address for communication within the allocated range for the ROM. Table 9.
  • Page 12 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Replacement of Spectrum Condenser Control Module (CCM) Replacement of one legacy Novar Spectrum CCM module requires installation of one XIO-CCM-S-H module. Table 11. Product Comparison (CCM). Product Family: Novar Spectrum XIO Spectrum Module: XIO-CCM-S-H Address Range:...
  • Page 13 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Replacement of Spectrum Analog Output Module (AOM) Replacement of one legacy Novar Spectrum AOM module requires installation of one XIO-AOM-S module. Table 12. Product Comparison (AOM). Product Family: Novar Spectrum XIO Spectrum Module: XIO-AOM-S Address Range:...
  • Page 14 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Table 13. Product Comparison (CIM2). (Continued) Product Family: Novar Spectrum XIO Spectrum Application Application programming can have links Spectrum: Programming: to 8 low temp sensor inputs from #1 to #8 Same functionality for up to 7 low temp sensor inputs and 1 digital input.
  • Page 15 XIO FAMILY OF SPECTRUM SYSTEM REMOTE INPUT/OUTPUT DEVICES Replacement of Spectrum Rack Input Module (RIM) Replacement of one legacy Novar Spectrum RIM module requires installation of up to three XIO-RIM-S and one XIO- RIMCT-s module. Table 15. Product Comparison (RIM). Product Family: Novar Spectrum XIO Spectrum...
  • Page 16: Regulatory Compliance

    No part of this document may be reproduced in any form or by any means without prior written permission from Novar. Honeywell Building Technologies In the U.S.: Honeywell 715 Peachtree Street NE ® U.S. Registered Trademark Atlanta, GA 30308 ©2020 Honeywell International Inc. 31-00360—01 M.S. 05-20 customer.honeywell.com Printed in United States...