Features and Options
MS-9600 PN 51335:E1 2/14/08
PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
Annunciators:
ACM Series-LED Zone Annunciators
LDM Graphic Annunciator Series
LCD-80F Liquid Crystal Display point annunciator
ACM-8RF Relay Module
Silence inhibit timer option per NAC
Autosilence timer option per NAC
Continuous, March Time, Temporal or California code for main circuit board
NACs with two-stage capability
Selectable strobe synchronization per NAC
Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules,
AFM annunciators or LCD-80F Remote annunciator
Auto-program (learn mode) reduces installation time. Reports two devices set to
the same address
Password and key-protected nonvolatile memory
User programmable password
Fully programmable from local keypad or keyboard or local PC
SLC operates up to 10,000 ft. (3,000 m) with twisted, shielded wire or 3,000 ft
(900 m) with untwisted, unshielded wire
Compatible with Fire•Lite newer series devices (CLIP Mode)
CP350 and CP355: addressable Ionization Smoke Detector
SD350(T) and SD355(T): addressable Photo Smoke Detector (T= with
Thermal Sensor)
H350(R) and H350(R): Fast Response Heat Detector (R=Rate-of-Rise option)
D350P(R): addressable Photo Duct Detector (R=alarm relay option)
B501BH & B501BHT Sounder Base
B224RB Relay Base
B224BI Isolator Base
MMF-300: Monitor Module
MMF-300-10: Monitor Module (10 Input Class B or 5 Input Class A)
MDF-300: Dual Monitor Module (uses two consecutive SLC addresses)
MMF-301: Miniature Monitor Module
MMF-302: 2-wire Detector Module
MMF-302-6: 2-wire Detector Module (6 Input Class B or 3 Input Class A)
CMF-300: Control Module
CMF-300-6: Control Module (6 Output Class B or 3 Output Class A)
CRF-300: Relay Module
CRF-300-6: Relay Module (6 Form-C relays)
BG-12LX: Manual Pull Station
I300: Isolator Module
Compatible with legacy Fire•Lite 300 Series devices (CLIP Mode only):
CP300: addressable Ionization Smoke Detector
SD300(T): addressable Photoelectric Smoke Detector (T= Thermal Sensor)
C304: Control Module
M300: Monitor Module
M301: Miniature Monitor Module
M302: 2-wire Detector Module
BG-10LX: Manual Pull Station
Optional 4XTMF module (conventional reverse polarity/city box transmitter)
Optional DACT-UD Digital Alarm Communicator Transmitter, reports up to 99
zones or 636 points (all devices) to a UL listed Central Station