Remote Operation Transmission - Hitachi UX Twin-Nozzle Technical Manual

Ink jet printer for industrial marking
Table of Contents

Advertisement

5.3.10 Remote Operation Transmission

5.3.10-1 Text
ESC2
[Existing machine message] Existing machine message can also be used.
ESC
5.3.10-2 Types of control
No.
Type
1
Operation start
2
Operation stop
Deflection
3
voltage control
(ON)
Deflection
4
voltage control
(OFF)
5
Fault clear
● Specify only one category of control at a time.
● Even if executing function is not possible, ACK will be answered, but no function will be executed.
5-36 ●Transmission Sequences
Header 72H
Type
Header 71H
Type
Types of control for operation
Starts to eject ink, and shifts from stop status to ready
status.
(Same process as with <Startup> button)
Stops ink ejection, and shifts to stop status
(Same process as with <Shutdown> button)
Turns deflection voltage on
(Same process as with <Ready> button in Manual
control menu window)
Turns deflection voltage off
(Same process as with <Standby> button in Manual
control menu window)
Closes the window for any fault that has occurred.
However, the window will remain if the cause of fault
is not resolved.
Type
30H:Operation start
31H:Operation stop
32H:Deflection voltage control (ON)
33H:Deflection voltage control (OFF)
34H:Fault clear
Content
Function enabled status
Stop status
When ink is being ejected
(standby, ready status, etc.)
Standby status
Ready status
When fault has occurred