6.9 Adjusting the pressure
● Check the pressure before printing state check at the start of operation.
● Do not perform this operation in the Stop state. Perform it in the state in which ink is ejected.
Open the Operation management screen.
1
(a) New HMI
Operation management
Ink Operating Time
0
h
Ink/Makeup
106 7K/S100A
Deflection Voltage
5.7
kV
5.7
Ambient Temperature
(Correct Range : 0-45)
20
℃
Print Count
0
HOME
OPEN
SAVE
Check the displayed ink pressure value of nozzle 1. If there is a difference of
2
0.010 or more from the standard value, adjust the pressure to the standard
value ±0.002 with a flat-blade screwdriver.
2018.07.07 12:45
×
STOP
OFFLINE
Ink Alarm Time
Cumulative Op.Time
(Standard Value : 1200)
1,200
h
Ink Pressure (Standard Value : 0.255)
Ink Viscosity
(Standard Value : 100)
0.255
100
0.255
Excitation V-ref ( Range : 0-19)
Excitation Frequency
9
68.9
9
Calibrate touch
screen coordinates
ADJUST
EDIT
SETTINGS
To raise the pressure : rotate clockwise.
To lower the pressure : rotate counterclockwise.
(b) Previous HMI
Operation management
0
h
Ink operating time
Ink alarm time
Cumulative op. time
MPa
Print count
000000000
Ink, makeup
Ink viscosity
kHz
Ink pressure (Nozzle2) 0 .255(MPa; standard value: 0 .255)
(Nozzle1) 0 .255(MPa)
Ambient temperature
Deflection voltage (Nozzle2)
(Nozzle1)
Excitation V-ref.
(Nozzle2)
(Nozzle1)
Excitation frequency
LOGIN
[Ready ]
Com=0
Makeup
0000
(hours)
1200
(hours; standard value: 1200)
000000
001200
(hours)
(prints)
1067K, S100A
100 (standard value:100)
20(℃; range: 5〜40)
5. 7 (kV)
5. 7 (kV)
11 (0〜19)
11 (0〜19)
68. 9 (kHz)
Pressure adjusting screw
●Adjusting the pressure 6-28