Remote Operation Transmission; Text; Types Of Control - Hitachi UX2 User Manual

Hide thumbs Also See for UX2:
Table of Contents

Advertisement

1.3.9

Remote Operation Transmission

1.3.9-1 Text

ESC2

1.3.9-2 Types of control

No.
Type
Operation start
1
Operation stop
2
Deflection
3
voltage control
(ON)
Deflection
4
voltage control
(OFF)
Fault clear
5
Specify only one category of control at a time.
Even if executing function is not possible, ACK will be answered, but no function will be executed.
Header 72H
Type
Types of control for operation
Starts to jet ink and shifts from stop status to
ready status.
(Same process as with <Startup> button)
Stops ink jet, and shifts to stop status (Same
process as with <Shutdown> button)
Turns deflection voltage on
(Same process as with <Ready> button in
Manual control menu window)
Turns deflection voltage off
(Same process as with <Standby> button in
Manual control menu window)
Closes the window for any fault that has
occurred.
However, the window will remain if the cause of
fault is not resolved.
Type
30H: Operation start
31H: Operation stop
32H: Deflection voltage control (ON)
33H: Deflection voltage control (OFF)
34H: Fault clear
Content
32
Function enabled status
Stop status
When ink is being jetted
(Standby, ready status,
etc.)
Standby status
Ready status
When fault has
occurred