Open the "Operation management" screen. Arbitrarily rotate the handle of
3
Pressure-reducing valve clockwise/counterclockwise and check if the
pressure changes. After confirming the change, adjust the valve and set the
Ink pressure to standard setting with a tolerance of 0.002.
(a) New HMI
Operation management
Ink Operating Time
Ink Alarm Time
(Standard Value : 1200)
0
1,200
h
Ink/Makeup
Ink Viscosity
(Standard Value : 100)
106 7K/S100A
100
Deflection Voltage
Excitation V-ref ( Range : 0-19)
5.7
kV
5.7
Ambient Temperature
(Correct Range : 0-45)
20
℃
Print Count
0
HOME
OPEN
SAVE
ADJUST
A special work is required when the Ink pressure does not change by rotating the
handle of Pressure-reducing valve. Contact your local distributor.
The "Startup process after Long-term shutdown" is now completed.
×
STOP
OFFLINE
2018.07.07 12:45
Cumulative Op.Time
0
h
h
Ink Pressure (Standard Value : 0.255)
0.255
MPa
0.255
Excitation Frequency
9
68.9
kHz
9
Calibrate touch
screen coordinates
EDIT
SETTINGS
LOGIN
CAUTION
(b) Previous HMI
[Ready ]
Operation management
0000
Ink operating time
1200
Ink alarm time
000000
Cumulative op. time
001200
Print count
000000000
1067K, S100A
Ink, makeup
Ink viscosity
100 (standard value:100)
Ink pressure (Nozzle2) 0 .255(MPa; standard value: 0 .255)
(Nozzle1) 0 .255(MPa)
Ambient temperature
20(℃; range: 5〜40)
Deflection voltage (Nozzle2)
5. 7 (kV)
(Nozzle1)
5. 7 (kV)
11 (0〜19)
Excitation V-ref.
(Nozzle2)
(Nozzle1)
11 (0〜19)
Excitation frequency
68. 9 (kHz)
2018.07.07 12:45
Com=0
Makeup
Ink
(hours)
(hours; standard value: 1200)
Manual
Shutdown
(hours)
HOME
(prints)
Back
●Long-term Shutdown 6-46