4.7 Examples of Transmission procedure

(1) When you change Character size of Item 1 of Nozzle 1 to "7x10":
Step 1. Write 7x10 on Character size of Item 1 of Nozzle 1 by Holding Register writing.
External unit
1 Write "7x10" on Character size of Item 1 of Nozzle 1 by Holding Register writing.
(Function code: 0x10)
[Request message data of Holding Register writing]
0000 0000 0009 01 10 1042 0001 02 0005
[Response message data of Holding Register writing]
0000 0000 0006 01 10 1042 0001
Holding Register writing request
Holding Register writing response
Contents of Request message
No.
Name
1
Transaction identifier
2
Protocol identifier
3
Data length
4
Device address
5
Function code
6
Start address
Data
7
No. of words to be written
8
No. of bytes to be written
9
Data to be written
Contents of Response message
No
Name
1
Transaction identifier
2
Protocol identifier
3
Data length
4
Device address
5
Function code
Data
6
Start address
7
No. of words to be written
(Hexadecimal notation)
Reflection in process
Request data
0x0000
0x0000
0x0009
0x01
0x10
0x1042
0x0001
0x02
0x0005
Response data
0x0000
0x0000
0x0006
0x01
0x10
0x1042
0x0001