Limitations on developing the Uniform Numbering Plan are as follows:
(1)
Station Number (Closed Numbering)
• The dialing number must be formed as follows:
XXXXXXXX
Station Number
(Maximum 8 digits)
Office Location Number
(Maximum 2 digits)
• When providing 3-digit or 4-digit station numbering within the No. 7 CCIS network, the data assign-
ment of the Originating Office Number (CMA7 Y=06) is not necessary because the Originating Of-
fice Number is included in the originating station number.
• LCR Group 3 (CM20 Y=0-3: A129) must be used for assigning an LCR access code.
(2)
Office Code and Station Number (Open Numbering)
• The dialing number must be formed as follows.
a
b
b
b
c
c
1
1
2
3
1
2
Office Code (b)
Access Code (a)
<
(a)
4 digits
<
(a) + (b)
4 digits
<
(c)
8 digits
a1  c1
c
c
c
c
c
c
3
4
5
6
7
8
Station Number (c)