Centralized Day/Night Mode Change-Ccis - NEC UNIVERGE SV9300 Networking Manual

Hide thumbs Also See for UNIVERGE SV9300:
Table of Contents

Advertisement

CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS

General Description
This feature switches the Day/Night Mode of a remote office, linked to the main office (2400 IPX) via
CCIS, in accordance with the Day/Night Mode switching on the Attendant Console at the main office.
• For Satellite Office
If the Attendant Console is required in the Satellite Office, the following programming is required.
START
CM60
Assign as ineffective Trunk Restriction Class
change by NT (Night) switch on DESKCON.
NOTE:
Assign as ineffective outgoing call restriction
on Night Mode by NT switch on DESKCON.
NOTE:
Assign as ineffective Day/Night Mode Change
by NT switch on DESKCON.
NOTE:
END
SATELLITE OFFICE
SV8300/
SV9300
DESCRIPTION
A reset by CM60 Y=90>0: 0 is
required after this data setting.
A reset by CM60 Y=90>0: 0 is
required after this data setting.
A reset by CM60 Y=90>0: 0 is
required after this data setting.
CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS
MAIN OFFICE
CCIS
2400 IPX
Y=02
(1)
0-7: DESKCON No.
(2)
1 : Ineffective
Y=04
(1)
0-7: DESKCON No.
(2)
1 : Ineffective
Y=06
(1)
0-7: DESKCON No.
(2)
1 : Ineffective
1-137
Chapter 1 CCIS FEATURES
ATT
DATA
NWA-088654-001 Rev.1.0
94ch1005.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents