NEC UNIVERGE SV9300 Networking Manual page 200

Hide thumbs Also See for UNIVERGE SV9300:
Table of Contents

Advertisement

To provide the LDN Diversion feature, the following programming is also required.
START
CM08
Provide the system with the LDN Diversion
feature.
CM58
Assign the data for LDN Diversion to each
indialed number assigned by CM50 Y=01.
Note that a call is diverted to LDN 0-7 keys as
specified by CM58 Y=02-07, even if CM50
Y=01, 1-8 has already been set.
A
DESCRIPTION
(1)
205
(2)
0: To provide
Y=00 Tenant No. of the LDN assigned by
CM50 Y=01
(1)
00
: Effective data in CM35 Y=015
01-08: LDN key 0-7 assigned by CM90
(2)
00-63: Tenant No.
Y=01 TAS Group No. assigned by
CM44>13
(1)
Same as CM58 Y=00
(2)
00-63: TAS Group No.
Y=02 Day Mode destination of the LDN
(1)
Same as CM58 Y=00
(2)
00-07: LDN key 0-7
08
: To TAS
09
: To station/outside party assigned by
CM58 Y=08
Y=03 Night Mode destination
(1)
Same as CM58 Y=00
(2)
00-07: LDN key 0-7
08
: To TAS
09
: To station/outside party assigned by
CM58 Y=09
Y=04 Day Mode diversion for busy desti-
nation station
(1)
Same as CM58 Y=00
(2)
00: To Attendant Console Busy key
08: To TAS
09: Camped on
Y=05 Night Mode diversion for busy desti-
nation station
(1)
Same as CM58 Y=00
(2)
Same as CM58 Y=04
1-186
Chapter 1 CCIS FEATURES
LDN NIGHT CONNECTION-CCIS
DATA
NWA-088654-001 Rev.1.0
94ch1005.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents