• To execute Local Loopback for PRT, do the following data programming.
START
CMAA
Set Local Loopback (PRT) ON.
END
• When the setting of more than 17 Highway Channels is required for a PRT blade, reassignment of
the Highway Channel (111 ch) allocation is required to each physical slot (slot01-06/07-12/13-18).
The programming for Highway Channel reassignment is as follows. For the details of Highway
Channel reassignment, refer to "CMF7 Y=9" in Command Manual.
START
CMF7
Reassign Highway Channel.
CME0
Execute the blade reset for all slots of the Unit
accommodated the DTI/PRT/CCT blade.
END
DESCRIPTION
DESCRIPTION
Y=22 Loopback setting
(1)
000-127: Trunk Blade No. assigned by
1 : Remote Loop Back (for PRT)
(2)
(FIFO unavailable)
2 : Payload Loop Back (for PRT)
(maintenance bit unavailable)
3 : Remote Loop Back (for PRT)
(FIFO available)
4 : Payload Loop Back (for PRT)
(maintenance bit available)
7 : Loop Back OFF (for PRT)
Y=9
(1)
XX YY
XX: 01-50: Unit No.
YY: 01/07/13: Lowest Slot No. within each
(2)
XX YY
XX: 01-50: Unit No.
YY: 06/12/18: Highest Slot No. within
Y=3
(1)
XX YY
XX: 01-50: Unit No.
YY: 01-18: Slot No.
(2)
XX YY
XX: 01-50: Unit No.
YY: 01-18: Slot No.
2-18
Chapter 2 Q-SIG FEATURES
PRT ASSIGNMENT
DATA
CM05 Y=1
DATA
Line/Trunk chassis
each Line/Trunk chassis