Honeywell VPR100 User Manual page 296

Table of Contents

Advertisement

Error Messages
Error
Temperature Constant
Not Programmed or Less
Than Zero
Temperature Input Not
Programmed or Less
Than Zero
Temperature Reference
Not Programmed or Less
Than Zero
Trend Has Too Many
Points For Rate Selected
Type Does Not Exist
Type Incompatible With
Hardware
Type Requires Hardware
Undefined Function
Block Request
Value Written to
Indirected Point
X Axis Must Increase
X Axis Not Increased
Enough
Y Axis Not Increased
Enough
280
Table 10-1 Error Messages (continued)
Description
F0 Sterilization CV Temperature constant is not
programmed or is less than zero.
F0 Sterilization CV Temperature Input is not
programmed or is less than zero.
F0 Sterilization CV Reference Temperature is
not programmed or is less than zero.
Data Storage cannot store more than 3 points
at 1/4 second scan rate.
A function block type was loaded that does not
exist. For example, you loaded a Profile but the
unit does not have the Profile option.
Analog output type is different from hardware
setting. For example, analog output is
programmed as current output (CAT) but
hardware is set to voltage output (VAT).
Hardware is missing for the programmed
analog output or discrete output relay.
Internal Error
An input has been connected and user has
tried to write a value to that input. For example,
if a control loop setpoint is connected to AI1
OV, you will receive this message if you try to
change the loop setpoint online.
Appears if AI is custom type or CV is Function
Generator and if Xn > Xn+1.
Appears if AI is custom type or CV is Function
Generator and if X does not increase by at least
0.00001.
Appears if AI is custom type or CV is Function
Generator and if Y does not change by at least
0.00001.
VPR & VRX – User Manual
User Action
Program Temperature constant with
value greater than or equal to zero.
Program Temperature input with
value greater than or equal to zero.
Program Reference Temperature
with value greater than or equal to
zero.
Change number of points to be
compatible with scan rate.
Re-program or re-load correctly.
Change programming to be
compatible the with hardware or vice
versa, then reload configuration or
reconfigure the block.
Either ignore the message knowing
that those particular points did not get
loaded or verify configuration and
make sure that the points that are in
the configuration match the hardware
components.
No user action
Avoid changing connected values.
Re-program Xn < Xn+1.
Re-program X.
Re-program Y.
12/00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrx100Vrx150

Table of Contents