07/11/02 09:10:10 61TA0000_110_0197
7. Connect ECM/PCM connector terminal A3 to body
ground with a jumper wire.
*03
8. Check for continuity between gauge control
module 32P connector terminal No. 30 and body
ground.
*04
Is there continuity?
YES
−
NO
PCM (A3) and the gauge control module.
ECM/PCM CONNECTOR A (49P)
CANH (WHT)
JUMPER WIRE
Terminal side of female terminals
GAUGE CONTROL MODULE 32P CONNECTOR
Wire side of female terminals
−
Go to step 9.
Repair open in the wire between the ECM/
9. Check for continuity between VSA modulator-
control unit 36P connector terminal No. 14 and
body ground.
VSA MODULATOR-CONTROL UNIT 36P CONNECTOR
CANH (WHT)
Is there continuity?
−
YES
Go to step 10.
NO
−
Repair open in the wire between the ECM/
PCM (A3) and the VSA modulator-control unit.
10. Check for continuity between yaw rate-lateral
acceleration sensor 5P connector terminal No. 3
CANH (WHT)
and body ground.
YAW RATE-LATERAL ACCELERATION SENSOR
5P CONNECTOR
Is there continuity?
−
YES
Go to step 11.
NO
−
Repair open in the wire between the ECM/
PCM (A3) and the yaw rate-lateral acceleration
sensor.
Wire side of female terminals
CANH (WHT)
Wire side of female terminals
11-197
*05
*06
(cont'd)