Replacing Fan Modules - Cisco UCS S3260 Service Manual

Storage server chassis
Hide thumbs Also See for UCS S3260:
Table of Contents

Advertisement

Chapter 3
Maintaining the System

Replacing Fan Modules

Each fan module contains two fans. See
You do not have to shut down or power off the system to replace fan modules because they are
hot-swappable. Do not operate the system with a fan module removed for more than one minute.
Each fan module has a fault LED that lights amber if the fan module fails.
Tip
Slide the system out the front of the rack far enough so that you can open the fan compartment cover.
Step 1
If you cannot safely view and access the component, remove the system from the rack.
Caution
Open the fan compartment cover as described in
Step 2
Remove the fan module:
Step 3
a.
b.
Install a new fan module:
Step 4
Note
a.
b.
Close the fan compartment cover and then push the system back into the rack.
Step 5
Figure 3-13
Fan Modules (Top View)
1
2
Grasp the two latches on the top of the fan and pinch them toward the center.
Lift the fan module straight out of the bay.
The arrow on the fan module that indicates the air flow direction should point to the rear of the
system.
Align the fan module with the bay so that the connector on the bottom of the fan module is aligned
with the socket on the floor of the chassis.
Lower the fan module until it touches the socket, then push down firmly until the latch locks.
1
2
3
Fan module fault LED
Fan module release latches
Figure 3-13
for the fan numbering.
Opening the Main Chassis Top Covers, page
3
Air flow direction arrow pointing toward rear of system
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Installing or Replacing System Components
3-12.
3-25