Appendix E
Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Reconnect power cables to the system. Wait for approximately five minutes to allow the system to boot up.
Step 6
Use the S3260 HUU for 3.1(3x) to upgrade the entire system to Cisco IMC release 3.1(3x).
Step 7
Note
Verify that all components were upgraded to Cisco IMC 3.1(3x).
Step 8
Check the firmware versions for the CMC, BMC, BIOS, SAS expander, and SIOC adapter.
Connect a KVM cable (Cisco PID N20-BKVM) to the KVM connector on the server node at the rear of the
Step 9
system. Connect a USB keyboard and a VGA monitor to the KVM cable.
Open the Cisco IMC Configuration Utility:
Step 10
Press and hold the front panel power button for four seconds to boot the system. Watch the screen for
a.
the prompt to press F8.
During bootup, press F8 when prompted to open the Cisco IMC Configuration Utility.
b.
This utility has three windows that you can toggle between by pressing F1 or F2.
The utility prompts you to change the default user password. Set a default user password before continuing.
Step 11
The following are the requirements for Strong Password:
The password can have minimum 8 characters; maximum 14 characters.
The password must not contain the user's name.
The password must contain characters from three of the following four categories:
Set the CMCs in all SIOCs and the BMCs in all server nodes to the factory defaults.
Step 12
The Factory Default check box has two options but you must perform two resets in this order:
Select Chassis Controller Configuration and save your changes. Both CMCs in the SIOCs are set to
a.
the factory default state.
Select Server Controller Configuration and save your changes. The server node is set back to its
b.
factory default state and the server/host reboots.
Note
When prompted, press F8 to enter the Cisco IMC Configuration Utility again.
Step 13
Configure the management, CMC, and BMC IP addresses for the system.
Step 14
If you use a DHCP server and you already have QSFP cables attached to the SIOC, the management IP
Note
address and network settings are already filled in. If you disable DHCP, you must set your own static
management IP address and network settings.
Upgrading From S3260 With One M4 Server Node to S3260 With One M5 Server Node
Use the from the S3260 downloads page, not the C3160 downloads page.
English uppercase letters (A through Z).
English lowercase letters (a through z).
Base 10 digits (0 through 9).
Non-alphabetic characters !, @, #, $, %, ^, &, *, -, _, =, "
The BMC reboots after resetting to defaults. Watch for the prompt to press F8 when the server
reboots in the next step.
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide