Cisco UCS S3260 Service Manual page 111

Storage server chassis
Hide thumbs Also See for UCS S3260:
Table of Contents

Advertisement

Appendix E
Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Using the Cisco IMC GUI:
Use the IP address of the CMC in either SIOC to log in to the Cisco IMC management software.
a.
Navigate to the following tab:
b.
Chassis > Inventory > Dynamic Storage > Zoning
Select the drives and then assign them to Server1 or Server2.
c.
Using the Cisco IMC CLI, enter the following commands with your choices:
Server# scope chassis
Server /chassis# scope dynamic-storage
Server /chassis/dynamic-storage# assign-drive <server ID> <drive-slotid-list>
For example:
Server# scope chassis
Server /chassis # scope dynamic-storage
svbu-huu-sanity-col2-1-vcmc /chassis/dynamic-storage # assign-drive server2 2
Are you sure you want to assign drives 2 to server2
Enter 'yes' to confirm -> yes
assign-drive operation successful.
Installing a Second Server Node or SIOC to the S3260 System With M5 Server Node
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
E-17