Cisco UCS S3260 Service Manual page 107

Storage server chassis
Hide thumbs Also See for UCS S3260:
Table of Contents

Advertisement

Appendix E
Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Installing a Second Server Node or SIOC to the S3260 System With M5 Server Node
If you are not using a DHCP server, use the Cisco IMC interface (CLI or GUI) to manually assign
a BMC IP address for the new server node.
For example using the CLI:
S3260-Server# scope network
S3260-Server /cimc/network# set v4-addr-bmc<n> <v4 ip-address>
S3260-Server /cimc/network# set v6-addr-bmc<n> <v6 ip-address>
For more information see Cisco UCS C-Series Integrated Management Controller GUI
Configuration Guide for S3260 Servers or the Cisco UCS C-Series Integrated Management
Controller CLI Configuration Guide for S3260 Servers here:
Configuration
Guides.
The second M5 server node is now ready for use in the S3260 system.