8. U-Turn Roller B

Note: There are 3 U-turn rollers B and they are
same parts. However, the control PCB
must be removed according to locations,
or only the guide plate for the option
PCB should be removed.
1) Remove the right and left covers.
(Page 3-3), (Page 3-5)
2) Remove the control PCB or the guide plate
for the option PCB.
(Page 3-13)
3) Remove the belt
fitting parts
2
and remove the gear
and pin
4
.
Note: Do not drop and lose the pin.
Figure 3-414
COPYRIGHT © CANON ELECTRONICS INC. 2008
1
. Unhook 2 pairs of the
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Remove the stop ring
removing the ball bearings
sides, remove the U-turn roller B
the rear cover side.
3
1
, and while
2
Figure 3-415
on both
3
from
3-29