Staple Pcb - Canon imageFORMULA DR-X10C Service Manual

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

2. Staple PCB

Note: The right and left staple PCBs are
symmetrical parts. Since the disas-
sembling procedure is the same and the
configuration is symmetrical, only the
disassembling procedure of the left
staple PCB is shown here. Disassemble
the right staple PCB by referring to the
disassembling procedure of the left
staple PCB.
1) Remove the upper front cover.
(Page 3-41)
2) Insert fingers into the clearance in the front
and remove the cable holder
bottom plate. Then, unhook the fitting parts
and rotate the staple detection unit
2
to the front.
Note: Before unhooking the fitting parts, re-
move the cable holder so that the cable
does not become stiff.
Note: If the space is too small to remove the
cable holder, remove the main drive
PCB and PCB mounting plate.
Figure 3-703
COPYRIGHT © CANON ELECTRONICS INC. 2008
3) Align the ends of the right and left shafts
Note: Do not pull it excessively because a
1
from the
3
4) Remove the screw
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
with the notch
1
of the mounting section,
and remove the staple detection unit
cable is connected to it. Since the coil
spring
3
is detached, do not lose it.
Figure 3-704
1
remove the cover
2
Figure 3-705
2
.
(M3, round tip) and
.
3-47