U-Turn Rollers - Canon imageFORMULA DR-X10C Service Manual

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

CHAPTER 3 DISASSEMBLY & REASSEMBLY

6. U-Turn Rollers

Note: There are 4 U-turn rollers. All of them
are same parts and can be disassem-
bled using the same disassembling
procedure.
1) Remove the upper unit.
(Page 3-42)
2) Remove
the
screen
post-imprinter. (3 M3 screws with round
tips)
Refer to "CHAPTER 4, INSTALLATION &
MAINTENANCE" for details.
(Page 4-12)
3) Remove 2 screws
remove the guide plate
screws
(TP head) on both sides and
3
remove the U-turn guide plate
Figure 3-809
3-54
plate
for
the
1
(M3, round tip) and
. Remove 6
2
.
4
COPYRIGHT © CANON ELECTRONICS INC. 2008
4) Open the end (marked with
bearing holders
the fitting parts, remove the U-turn roller
unit.
Note: For other precautions and subsequent
procedures, refer to the "Reading Roller
(Front)" section.
Figure 3-810
Notes on assembling
The positioning of the guide plate and
U-turn guide must match the positioning of
the side plate correctly.
) of both
1
, and while unhooking
CANON DR-X10C FIRST EDITION

Hide quick links:

Advertisement

Table of Contents
loading