Image Processing Control - Canon imageFORMULA DR-X10C Service Manual

Hide thumbs Also See for imageFORMULA DR-X10C:
Table of Contents

Advertisement

3. Image Processing Control

This machine performs main image
processing using the hardware in the main
body to speed up image processing.
Reading PCB
Frame CIS
(Right/left)
Scanner controller (IC108)
Image input
section
Data rearrangememt
Frame sensor
processing
section
Frame detection
DMA I/F
SCSI/USB
controller
COPYRIGHT © CANON ELECTRONICS INC. 2008
Image CIS
(Front/Back)
300/600 dpi, analog
A/D conversion
Shading correction
Line alignment
Grayscale conversion
Dropout (RGB)
300/600 dpi, digital
processing
Resolution conversion
Moire reduction
Color pixel
counter
Auto image
type detction
JPEG
module
JPEG
compression
SDRAM
64 Mbytes
Figure 2-403
CANON DR-X10C FIRST EDITION
CHAPTER 2 FUNCTION & OPERATION
Figure 2-403 shows the block diagram of
the image processing in the main body.
Image
section 1
Image
processing
section 3
Edge emphasis
Binarization
ATE-II
SDRAM
384 Mbytes
SDRAM
I/F
Image rotation
Image interpolation
Data storage
3-D color
correction section
Color correction
Dropout
(Custom)
Image
processing
section 2
Resolution conversion
1-D gamma correction
Grayscale conversion
Binary ABC
Blank skip
Prevent bleed-through
Moire reduction
2-23