CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Pull out both ends of the lock plate of the
connector
1
using the clips and remove
the flat cable
2
. In the same way, remove
the flat cable on the opposite side.
Then, remove 2 screws
self-tapping) and turn the reading PCB
over.
Note: Do not pull it excessively because the
cables are connected to it.
Figure 3-906
Notes on assembling
When the lock plate of the connector is
open, insert the flat cable into the con-
nector until the contact surface of the flat
cable is entirely covered and then close the
lock plate.
When mounting the PCB in the case, align
the end surface of the PCB with the end
surface of the sponge of the case and
press it. The PCB must not ride on the
sponge.
3-60
3
(M3, TP head,
4
COPYRIGHT © CANON ELECTRONICS INC. 2008

3. Blower

1) Remove the reading unit.
(Page 3-58)
2) While unhooking the fitting parts
and remove the blower
ting parts
2
are removed.
Note: If the fitting parts
sively, they may be damaged.
Figure 3-907
Notes on assembling
Insert the blower discharge opening
into the opening in the reading unit. While
aligning 2 pairs of the fitting parts
the blower in.
Figure 3-908
1
, tilt
3
so that the fit-
1
are bent exces-
1
2
, push
CANON DR-X10C FIRST EDITION