III. MAINTENANCE

1. User Maintenance

A list is shown below. Refer to the "User Manual" for the details.
No.
Location/parts
1
Main body
2
Pickup inlet/feed path
3
Pickup roller
Feed roller
Retard roller
4
Platen roller
5
Other rollers
6
Reading glass
7
Ink cartridge
8
Parts to which ink is
attached
(Pre-imprinter)
Note 1: The supplied cleaning cloth is used to clean the reading glass and rollers.
Note 2: Clean with the supplied roller cleaning sheet in the user mode.
Note 3: If the number of sheets fed with the roller exceeds 500,000 sheets, a replacement
message is displayed on the operation panel LCD and computer screen.
Note 4: When the [Start] key on the operation panel is pressed, the LED on the reading unit
lights and stains on the reading glass can be confirmed.
Note 5: The expected life of the ink cartridges is not shown on the "User Manual".
Note 6: Since post-imprinter parts are not easily available, they are not described in the "User
Manual".
COPYRIGHT © CANON ELECTRONICS INC. 2008
Intervals
As
500,000
required
sheets
Table 4-301
CANON DR-X10C FIRST EDITION
CHAPTER 4 INSTALLATION & MAINTENANCE
[ : Cleaning,
Details
Wipe the main body with a cloth
dipped into water and wrung tightly,
then wipe dry.
Using a blower, etc., remove remained
dust and paper powder.
Wipe the rollers with a cloth dipped
into water and wrung tightly, then wipe
dry. The expected life is 500,000
sheets. Refer to Note 3.
Press the [Stop] key on the operation
panel, and while rotating it gradually,
clean the black and white background
section in the same way as for the
above roller. Remove the brush sec-
tion with a cotton swab, etc.
Clean in the same way as for the
above roller.
Wipe the reading glass with a cloth
dipped into water and wrung tightly,
then wipe dry. Refer to Note 4.
Clean the discharge outlet of the ink
head with soft cloth or paper or a cot-
ton swab. Refer to Note 5 for re-
placement time.
Wipe these parts with a cloth dipped
into water and wrung tightly, then wipe
dry. Refer to Note 6.
: Replace]
4-21

Hide quick links:

Advertisement

Table of Contents
loading