CHAPTER 3 DISASSEMBLY & REASSEMBLY
V. BASE UNIT-3 (READING SYSTEM)
Note: If the reading unit is disassembled fur-
ther, be careful to prevent entry of dust.
Do not touch the inner surfaces of glass
and the surfaces of the lens array with
fingers. If they are dirty, clean them with
a clean dry cloth.
If the inside is not disassembled, re-
place the entire reading unit.
Note: The differences between the parts of the
reading unit (upper) and the reading unit
(lower) are the cable cover and flat ca-
ble. The wiring of some cables and the
direction of assembly are different.

1. Reading Unit (Lower)

1) Remove the left cover.
(Page 3-5)
2) Remove the platen roller (lower).
(Page 3-24)
3) Unhook 2 pairs of the fitting parts
remove the gear
reading roller (middle).
Note: Do not drop and lose the pin.
Figure 3-501
3-32
1
and
2
and pin
3
for the
COPYRIGHT © CANON ELECTRONICS INC. 2008
4) Remove the stop ring
moving the ball bearings
remove the reading roller (middle)
Figure 3-502
5) Remove the screw
remove the support plate
way, remove the support plate on the
opposite side.
Figure 3-503
1
and while re-
2
on both sides,
3
.
(M3, round tip) and
1
. In the same
2
CANON DR-X10C FIRST EDITION