Monitoring Operating Status Using The Icim - Cisco Prisma II Installation And Operation Manual

Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Monitoring Operating Status Using the ICIM

Monitored Parameters
You can monitor the status of operating parameters. The table below describes the
monitored parameters for this module.
Parameter
+1_8VInt
+3_3VInt
Las1Inst
LasBias1
LasTemp1
Las1Type
Las2Inst
LasBias2
LasTemp2
Las2Type
ProcTemp
Clk_Src
3-16
Units
Function
V
1.8 voltage level internal to the transmit processor.
V
3.3 voltage level internal to the transmit processor.
0 Inst or
Indicates if transmitter sub-module is installed.
1.0 Inst
0 Inst = not installed. 1.0 Inst =installed.
mA
Laser 1 bias current in mA.
delC
Laser 1 temperature in degrees C relative to its target
temperature
0 or 3
Indicates what type of transmitter is installed.
0 = 1550 nm cooled laser transmitter
3 = Uncooled 1550 nm or 1310 nm laser transmitter
0 Inst or
Indicates if transmitter sub-module is installed.
1.0 Inst
0 Inst = not installed. 1.0 Inst =installed.
mA
Laser 2 bias current in mA.
delC
Laser 2 temperature in degrees C relative to its target
temperature.
0 or 3
Indicates what type transmitter is installed.
0 = 1550 nm cooled laser transmitter
3 = Uncooled 1550 nm or 1310 nm laser transmitter
C
Temperature of the transmit processor in degrees C.
Indpend
Indpend - The transmitter generates the clock signal
Master
but does not send it outside the module.
Slave
Master - The transmitter generates it's own clock
signal and sends it out.
Slave - Uses the clock input supplied from the
backplane, typically from another transmitter in
Master mode. If the clock is not present clock alarms
are generated.
Operation Using the ICIM