Cisco Prisma II Installation And Operation Manual page 61

Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Checking bdr Transmit Processor Alarms Using the ICIM,
Alarm Thresholds
Alarm thresholds are shown below. Alarm thresholds are not adjustable on this
module.
Alarm
Function
+1_8VInt
Internal 1.8
voltage
+3_3VInt
Internal 3.3
voltage
ProcTemp
Module
temperature
LasBias1
Bias current
of the laser in
transmitter 1
LasBias2
Bias current
of the laser in
transmitter 2
Lsm1Temp
Laser 1
temperature
(cooled laser
only)
Lsm2Temp
Laser 2
temperature
(cooled laser
only)
Lsm1EOL
Laser 1 end
of life
monitor
Lsm2EOL
Laser 2 end
of life
monitor
3-26
Major
Minor
Minor
Low
Low
High
Thhold
Thhold
Thhold
1.620
1.67
1.93
2.970
3.070
3.530
-40
-10
80
5.0
8.0
32.5
5.0
8.0
32.5
-1.0
N/A
N/A
-1.0
N/A
N/A
34
N/A
N/A
34
N/A
N/A
Operation Using the ICIM
Continued
Major
High
Unit
Thhold
Typical range
1.980
V DC
1.77 – 1.83
3.630
V DC
3.2 – 3.4
85
40-50
°C
40
mA
10 to 30
40
mA
10 to 30
N/A
mA
0.00 to 0.15
N/A
mA
0.00 to 0.15
N/A
mA
34 mA for
cooled lasers;
100 mA for
uncooled
lasers
N/A
mA
34 mA for
cooled lasers;
100 mA for
uncooled
lasers
78-715192-01 Rev C

Advertisement

Table of Contents
loading

Table of Contents