Key:
Plain = Read only
Measured Products
Meas. Prod. Ref. Image.
Config. DC Param.
Lower Prod DC
Upper Prod DC
Vapor DC
Max. Filling Rate
Sensor Height
Max. Product Level
Level Offset
Probe Length
Measurement Range
Details Image
Page 18
Table 4 - Basic Configuration parameters, cont'd
Bold = Configurable
Bold underline = Method
Process
Single Liquid
Two Liquids, Flooded
Two Liquids, Non- Flooded
Vapor DC
Product DC
Upper Prod DC
Lower Prod DC
#
Measurement
See A in image
See B in image
See C in image
SLG 700 Series HART Option User's Manual
Bold italic = Table or graph
Select measured product.
Provides the image based on configured
measured product.
Single Liquid
Two Liquids Flooded
Two Liquids Non-Flooded
Select dielectric constant (DC) values for
measured product. A drop down list of
typical products and their DCs is provided.
.
For single liquid this is Product DC.
Enter Maximum filling/emptying speed.
Enter probe length.
Revision 5