External AC/DC Power Supply
The optional external AC/DC power supply is for use in environments, such as an office, where DC power is not avail-
able.
Note: The Honeywell-approved AC/DC Power Supply and Adapter Cable are only intended for use in a 25ºC (77ºF)
maximum ambient temperature environment.
In North America, this unit is intended for use with a UL Listed ITE power supply with output rated 10 – 60 VDC, mini-
mum 15W. Outside North America, this unit is intended for use with an IEC certified ITE power supply with output
rated 10 – 60 VDC, minimum 15W.
The external power supply may be connected to either a 120V, 60Hz supply or, outside North America, to a 230V,
50Hz supply, using the appropriate detachable cordset. In all cases, connect to a properly grounded source of supply
provided with maximum 15 Amp overcurrent protection (10 Amp for 230V circuits).
Connect External Power Supply
1. Connect the provided detachable cordset (US only, all others must order cable separately) to the external
power supply (IEC 320 connector).
2. Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains).
3. Connect the DC Output Cable end to the corresponding connector on the Adapter Cable.
4. Connect the watertight connector end of the Adapter Cable to the Thor VM3 Smart Dock Power Connector by
aligning the connector pins to the power connector; push down on the watertight connector and twist it to fas-
ten securely.
5. Press the
6. Press the
4 - 38
AC Input Cable (US only)
To DC Output Cable
Power Switch
(page 3-4) on the back of the Thor VM3 dock.
Power Button
(page 3-4) on the front of the Thor VM3 to turn on the Thor VM3.
DC Output Cable