The Thor VM3 has external power but vehicle ignition is Off. The Power button is pressed.
Result
The Thor VM3 boots. Once booted the Thor VM3 follows the Ignition Control/Ignition Off power scheme with
timers reset after the boot completes.
Thor VM3 is Off and Vehicle Ignition is Switched to On
Conditions
The Thor VM3 is Off and vehicle ignition changes from Off to On.
Result
The Thor VM3 boots. Once booted the Thor VM3 follows the Ignition Control/Ignition On power scheme with
timers reset after the boot completes.
Thor VM3 is On and Vehicle Ignition is Switched to On
Conditions
The Thor VM3 is On and vehicle ignition changes from Off (or not present) to On.
Result
The Thor VM3 continues to run and follows the Ignition Control/Ignition On power scheme with timers reset at
the time Ignition switched to Active.
An example of this case would be a Thor VM3 that is running on UPS and is then mounted on a dock that has
truck power and the ignition switch is already On.
Thor VM3 is On and Vehicle Ignition is Switched to Off
Conditions
The Thor VM3 is On and vehicle ignition changes from On to Off.
Result
The Thor VM3 follows the Ignition Control/Ignition Off power scheme with timers reset at the time Ignition
switched to Inactive. UPS charging is disabled.
An example of this case would be a Thor VM3 that is running on UPS and is then mounted on a dock that has
truck power and the ignition switch is already Off.
Auto-On Mode
In Auto-On mode, the Thor VM3 is turned On by the presence of external power with no user interaction
required. Ignition input is ignored when Auto-On Mode is enabled.
Thor VM3 is Off
Conditions
The Thor VM3 is Off and gets external power, such as
• Thor VM3 is installed on a powered Quick Mount Smart Dock with the dock power switch On
• Thor VM3 is already mounted to a dock and external power is applied to the dock
• Thor VM3 is already mounted to a dock and the dock power switch is turned On
Result
The Thor VM3 boots. Once booted the Thor VM3 follows the Auto-On power scheme with timers reset after
the boot completes.
Thor VM3 is On
Conditions
The Thor VM3 is On and gets external power, such as