Details Of Input Signals (Qd75Mh Plc Cpu) - Mitsubishi Electric MELSEC-QD75MH1 User Manual

Positioning module
Table of Contents

Advertisement

3 SPECIFICATIONS AND FUNCTIONS
3.3.2 Details of input signals (QD75MH
Device
Signal name
No.
X0
QD75 READY
X1
Synchronization
flag
X4
Axis 1
M code ON OFF: M code is
X5
Axis 2
X6
Axis 3
X7
Axis 4
X8
Axis 1
Error
detection
X9
Axis 2
XA
Axis 3
XB
Axis 4
XC
Axis 1
BUSY
1
XD
Axis 2
XE
Axis 3
XF
Axis 4
X10
Axis 1
Start
complete
X11
Axis 2
X12
Axis 3
X13
Axis 4
X14
Axis 1
Positioning
X15
Axis 2
complete
X16
Axis 3
2
X17
Axis 4
The ON/OFF timing and conditions of the input signals are shown below.
ON: READY
• When the PLC READY signal [Y0] turns from OFF to ON, the parameter setting
OFF: Not READY/
range is checked. If no error is found, this signal turns ON.
Watch dog
• When the PLC READY signal [Y0] turns OFF, this signal turns OFF.
timer error
• When watch dog timer error occurs, this signal turns OFF.
• This signal is used for interlock in a PLC program, etc.
OFF: Module
• After the PLC is turned ON or the CPU module is reset, this signal turns ON if the
access
access from the CPU module to the QD75MH is possible.
disabled
• When "Asynchronous" is selected in the module synchronization setting of the CPU
ON: Module
module, this signal can be used as interlock for the access from a PLC program to
access
the QD75MH.
enabled
• In the WITH mode, this signal turns ON when the positioning data operation is
not set
started. In the AFTER mode, this signal turns ON when the positioning data
ON: M code is
operation is completed.
set
• This signal turns OFF with the "
• When M code is not designated (when"
OFF.
• With using continuous path control for the positioning operation, the positioning will
continue even when this signal does not turn OFF. However, a warning will occur.
(Warning code: 503)
• When the PLC READY signal [Y0] turns OFF, the M code ON signal will also turn
OFF.
• If operation is started while the M code is ON, an error will occur.
OFF: No error
• This signal turns ON when an error listed in Section 15.1 occurs, and turns OFF
when the error is reset on "
ON: Error
occurrence
OFF: Not BUSY
• This signal turns ON at the start of positioning, OPR or JOG operation. It turns OFF
ON: BUSY
when the "
remains ON during positioning.) This signal turns OFF when the positioning is
stopped with step operation.
• During manual pulse generator operation, this signal turns ON while the "
Manual pulse generator enable flag" is ON.
• This signal turns OFF at error completion or positioning stop.
OFF: Start
• This signal turns ON when the positioning start signal turns ON and the QD75MH
incomplete
starts the positioning process.
ON: Start
(The start complete signal also turns ON during OPR control.)
complete
Positioning start signal [Y10]
Start complete signal [X10]
OFF: Positioning
• This signal turns ON for the time set in "
incomplete
time" from the instant when the positioning control for each positioning data No. is
ON: Positioning
completed.
complete
(It does not turn ON when "
• If positioning (including OPR), JOG/Inching operation, or manual pulse generator
operation is started while this signal is ON, the signal will turn OFF.
• This signal will not turn ON when speed control or positioning is canceled midway.
PLC CPU)
PLC READY signal [Y0]
OFF
QD75 READY signal [X0] OFF
Cd.7
Axis error rest".
Cd.5
Da.9
Dwell time" has passed after positioning stops. (This signal
Pr.40
3 - 15
Details
ON
ON
M code OFF request".
Da.10
M code" is "0"), this signal will remain
ON
OFF
ON
OFF
Pr.40
Positioning complete signal output
Positioning complete signal output time" is "0".)